Part Number Hot Search : 
HT95R24 IRFU211 AN1657 A2F1CSP LS3013 4805D T5551 100LT
Product Description
Full Text Search
 

To Download NLP250MEDICAL0910 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Embedded Power for Business-Critical Continuity
NLP250 Medical Series
Single Output
Rev.10.1.09_181 NLP250 Medical Series 1 of 4
Total Power: 250W Input Voltage: 85-264VAC # of Outputs: Single
Special Features
* Medicalsafeties * ActivePFCand EN61000-3-2 compliant * 250Wonmainchannelwith forced air * Lowprofilefits1Uapplications * U-Channelformaximum thermalperformance * Optionalcover(CJsuffix) * 5Vstandbyoutput * 12Vfanoutput * Integratedcontroland monitoring features * Overcurrent,overvoltageand overtemperatureprotection * CompliancetoEN55022-B conducted noise standard * DualACfuses * RoHScompliant * 2yearwarranty
ElectricalSpecifications
Input
Inputvoltagerange: Inputfrequencyrange: Inputsurgecurrent: Safetygroundleakagecurrent: Inputcurrent: Inputfuse: 264Vac(coldstart) 264Vac,50Hz 120Vac@250W 230Vac@250W UL/IEC127 200LFMforcedair 250LFMwithcover Mainoutput Mainoutput Auxiliaryoutputs @120VacInput Mainoutput 50-100% Stepat0.5A/s Mainoutput Cyclic operation Singles 5Vsb 12V(fan) Universalinput 85-264Vac 47-63Hz 40Amax. 150A 2.78Arms 1.36Arms T6.4AH,250VacInliveand neutral 250watts 5% 2.0% 5.0% 2.0smax. 5.0%or250mV max.dev.,1msmax recoveryto1% 0.02%/C 115%,5% Continuous 0A 5V@1.0A 12V@0.3A
Output
Maximumpower: Adjustmentrange: Totalregulation: (lineandload) Turn-ondelay: Transientresponse:
Safety
* * * * VDE0750/EN60950 IEC950/IEC60601-1 FileNo.1177400-3336-0759 UL60601-1 FileNo.E186249 CertificateNo.40014041 CBRefDE1-36628
Temperaturecoefficient: Overvoltageprotection: Shortcircuitprotection: Minimumoutputcurrent: Auxiliaryoutputs: (SeeNote8,page3)
Allspecificationsaretypicalatnominalinput,fullloadat25Cunlessotherwisestated
Embedded Power for Business-Critical Continuity
Rev.10.1.09_181 NLP250 Medical Series 2 of 4
EMCCharacteristics(5)
Conductedemissions: Harmoniccurrentcorrection: Voltageflicker: ESDair: ESDcontact: Radiatedimmunity: Fasttransients: Surge: Conductedimmunity: Voltagedips: EN55022,FCCpart15 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 85Vac@50Hz 115Vac@250W 230Vac@250W Input/output Input/chassis LevelB Compliant Compliant Level3 Level3 Level3 Level3 Level3 Level3 Compliant 20ms@250W 84%typ. 86%typ. 4000Vac 2000Vac 650g(22oz) TelcordiaSR-332 MIL-HDBK-217F 317,000hoursmin. 158,000hoursmin.
GeneralSpecifications
Hold-uptime: Efficiency: Isolationvoltage: Safetyapprovals(seeNote6,page3): Weight: MTBF(@25C):
UL/cULUL60601-1,VDEEN60601-1,CAN/CSA22.2No.601-1
EnvironmentalSpecifications
Thermalperformance: Operatingambient, (Seederatingcurve) Non-operating 0Cto50Cambient, 200LFMforcedair 250LFMwithcover 0Cto50Cambient, 0Cto40Cwithcover Convectioncooled 50Cto70Cambient, Convectioncooled Relativehumidity: Altitude: Vibration(SeeNote7,page3): Shock: Non-condensing Operating Non-operating 5-500Hz PerMIL-STD-810E Deratelinearly to50%load 5-95%RH 10,000feetmax. 30,000feetmax. 2.5Grmspeak 516.4PartIV 175W -40Cto+85C 250W 0Cto+70C
Embedded Power for Business-Critical Continuity
OrderingInformation
OutputVoltage 12V 24V
Notes
Rev.10.1.09_181 NLP250 Medical Series of 4
Output Current Min 0A 0A Max(freeair)(1,4) Max(forcedair)(2,4) 14.6A 7.3A 21A 10.5A
Ripple(3) 120mV 240mV
TotalRegulation 2.0% 2.0%
ModelNumbers(9,10) NLP250N-99S12J NLP250N-99S24J
1 Freeairconvection.Maximumcontinuousoutputpowernottoexceed175 W. RefertoFigure1forthederatingcurve. 2 200LFM(250LFMwithcover)forcedaircoolingfromthelongerside. Maximumcontinuousoutputpowernottoexceed250W. 3 Figure is peak-to-peak for room temperature rating. Output noise measurementsaremadeacrossa20MHzbandwidthusinga6inchtwisted pair,terminatedwitha10Ftantalumcapacitoranda0.1Fceramic capacitor. 4 CAUTION:Allowaminimumof1secondafterdisconnectinglinepowerwhen makingthermalmeasurements.Foroptimumreliabilitynopartoftheheatsink shouldexceed115Candnosemi-conductorcasetemperatureshouldexceed 120 C.
5 Noexternalfilteringrequiredduringconductedemissionstestingbutsome applicationsmayrequireadditionalfilteringtoachievesystemcompliance. CompliancewithradiatedEMIspecificationsmayrequiremountingina suitable enclosure. 6 Thisproductisonlyforinclusionbyprofessionalinstallerswithinother equipmentandmustnotbeoperatedasastandaloneproduct. 7 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4G 8 5Vsb(standby)outputisavailablewheneverACispresent,regardlessof remoteON/OFFsignalstatus.12V(fan)presentwhenmainoutputispresent. 9 The`J'suffixindicatesthatthesepartsarePb-free(RoHS6/6)compliant. "CJ"suffixindicatescoveredRoHSversion. 10 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal EmersonNetworkPowerrepresentativeorusetheon-linemodelnumber searchtoolathttp://www.PowerConversion.comtofindasuitablealternative.
MechanicalDrawing
CUSTOMER MOUNTING HOLES MAX. SCREW PENETRATION 0.08IN 6-32 J1
4.000 [101.60]
E L N
1 J3 JP1 VR7 J4 J2
1.140 (28.96)
1
0.750 (19.05)
M3.0 5.850 (148.59)
1 0.25 (6.35)
6.250 (158.75) M3.0 4 PLACES
7.000 [177.80]
6-32 4 PLACES
4.700 (119.38) 1.500 [38.10] 5.500 (139.70) BOTTOM VIEW
2.500 (63.50)
Embedded Power for Business-Critical Continuity
Figure1:DeratingCurve OutputPower(Watts)
DERATING CURVE Output Power (Watts) All Models Forced Air 250 W 200 LFM (1.0 m/s) FORCED AIR COOLING 175 W 24 V Free Air
Figure1b:DeratingCurveWithCover OutputPower(Watts)
DERATING CURVE Output Power (Watts) WITH COVER All Models Forced Air
Americas
Rev.10.1.09_181 NLP250 Medical Series 4 of 4
250 W 250 LFM (1.25 m/s) FORCED AIR COOLING 175 W
24 V Free Air
12 V Free Air
5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698
12 V Free Air 125 W NATURAL FREE AIR CONVECTION COOLING 75 W
125 W NATURAL FREE AIR CONVECTION COOLING 87 W 75 W
Europe (UK)
0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355
ConnectorandMatingConnectorTypes
Asia (HK)
Connector
J1 J2 J3
Type
MatingConnectorType
Molex09-65-2058(5273series)voidpins Molex09-50-8051orequivalentwithMolex08-52-0113or 2and4orequivalent equivalentcrimpterminals Molex22-23-2021(6373series)or equivalent Molexterminalblock387007504or equivalent Molex22-23-2091(6373series)or equivalent Molex22-01-3027(2695series)orequivalentwithMolex 08-50-01113(2759series)orequivalentcrimpterminals Terminalblockcontains#6-32screwwithclamp washersuitableforwiresize12-22awg(0.5-2.5mm2). MaxTorquetp1.36Nm(12in.lb) Molex22-01-3097(2695series)orequivalentwithMolex 08-50-0113(2759series)orequivalentcrimpterminals
14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888
Forglobalcontact,visit:
www.PowerConversion.com techsupport.embeddedpower @emerson.com
Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis information or for any errors or omissions.
J4
Pin Connections
J1
Pin 1 Pin 2 Pin 3 Ground/Earth Live Neutral
Pin Connections Continued
J2
Pin 1 Pin 2 +12V SGND Vo Vo RTN RTN +S -S LS PS OFF PS ON SGND PWOK 5Vsb DCOK FanVoltage Return +MainOutput +MainOutput MainReturn MainReturn +VoRemoteSense VoRemoteSense LoadShareSignal RemoteON/OFFsignalNO RemoteON/OFFsignalNC Signal Common PowerGood Stand-byVoltage DCPowerGoodSignal
Emerson Network Power. Thegloballeaderinenabling business-critical continuity. ACPower Connectivity DCPower Embedded Computing Embedded Power Monitoring Outside Plant PowerSwitching&Controls Precision Cooling Racks&IntegratedCabinets Services Surge Protection EmersonNetworkPower.com
EmersonNetworkPowerandtheEmerson Network Power logo are trademarks and servicemarksofEmersonElectricCo. (c)2009EmersonElectricCo.
J3
Pin 1 Pin 2 Pin 3 Pin4
J4
Pin 1 Pin 2 Pin 3 Pin4 Pin5 Pin 6 Pin7 Pin 8 Pin9


▲Up To Search▲   

 
Price & Availability of NLP250MEDICAL0910

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X